Model:DDTE081B
DDTE081B Integrated Outdoor Telecom Cabinet
1. Application
The DDTE081B Integrated Outdoor Telecom Cabinet is mainly used in wireless communication base station, such as 3G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.
2. Features
(1) The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.
(2) Cabinet cooling: heat exchanger and air conditioner. (Other cooling option: fans). MTBF≥50000h
(3) The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There are entrance holes individually for power cable, signal cable and optical cable.
(4) All the cables used in the cabinet are made from flame retardant materials.
3. Technical Parameters
Item |
Type |
Technical Parameter |
Structure |
Dimension |
External Dimension: W×D×H 900×900×2100mm
Internal Dimension: W×D×H 800×800×1800mm |
Layout |
1 compartment |
|
Equipment Installation Method |
Upper compartment: 19” rack; Lower compartment: battery shelf. |
|
Door |
With one front door, and special lock for outdoor cabinet (support padlock) |
|
Material |
Galvanized steel, 1.5mm thick outer plate, 0.8mm thick inner plate |
|
Heat Insulation |
There are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF. |
|
Structure |
Assembled |
|
Ingress Protection |
IP55 |
|
Temperature Control |
Cooling |
AC220V air conditioner and DC48V heat exchanger |
Lighting |
LED lamp |
48V LED lamp |
Temperature |
Temperature |
|
|
|
|
|
|
|
Humidity |
Relative Humidity |
5% ~ 100% |
Pressure |
Air Pressure |
62kpa ~ 101kpa (similar to 0m ~ 5000m altitude) |
Radiation Intensity |
Solar Radiation Intensity |
1120 ×(1±5%)W/m2 |
No. |
Item |
Quantity |
Unit |
Specs |
1 |
Outdoor Telecom Cabinet |
1 |
Set |
(1) External Dimension:W*D*H 900*900*2100mm Internal Dimension:W×D×H 800×800×1800mm (2) Two compartments: the upper part is equipment compartment, the lower part is battery compartment (3) With one front door, and special lock for outdoor cabinet (support padlock)
(4) Material: galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate;
(5) There are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF. |
2 |
Air Conditioner
(cooling for battery compartment) |
1 |
Set |
Cooling capacity: 300W;
Input voltage: AC220V, 50HZ;
Model: TC06-030JFH/01(KT033). |
3 |
Heat Exchanger (cooling for equipment compartment) |
1 |
Set |
Cooling capacity: 150W/K;
Input voltage: DC48V;
Model: HE06-150SEH/01(CW031). |
4 |
Environment Monitoring Unit |
1 |
Set |
19”, 1U; Model: SM2400. |
5 |
Door Sensor |
2 |
PC |
One for controlling LED lamp, one for open door alarm. |
6 |
Smoke Sensor |
1 |
PC |
|
7 |
Water Sensor |
1 |
PC |
|
8 |
Temperature and Humidity Sensor |
1 |
PC |
|
9 |
LED Lamp |
1 |
PC |
DC48V |
10 |
Power Distribution Unit |
1 |
Set |
Grade B Lightning Proof AC Input: 63A/2P *1;
AC Output: 16A/1P*4;
DC Output: 16A/1P*4
Input Voltage: AC220V. |
11 |
DC48V Power System |
1 |
Set |
Model: GPE4890B (DC48V, 90A)
Including:
(1) 3×30A Rectifier Module;
(2) 1× Monitoring Module;
(3) 1× Rack, 19”, 2U, DC output: 40A*4 (load), Battery output: 70A*1 (battery). |
12 |
Package |
1 |
Set |
Wooden Case |